Dual Wave C Electromagnetic and Pneumatic Shockwave Therapy Machine ESWT
$3,599.00
Excluded Tax
Professional Dual-Technology Shockwave Therapy System
Electromagnetic and Pneumatic Shockwave Technology for Multi-Application Treatments
The Wikbeauty Dual Wave C is a professional extracorporeal shockwave therapy system that combines electromagnetic and pneumatic ballistic technologies on one integrated platform.
Its electromagnetic handpiece provides focused acoustic energy for precise treatment areas, while the pneumatic handpiece generates radial pressure waves for broader soft-tissue applications. Practitioners can select the appropriate technology according to the treatment area and professional protocol.
The system includes 19 treatment tips, three dedicated treatment interfaces, a 10.4-inch color touchscreen, adjustable energy and frequency settings, a built-in cooling system, and an impact counter.
Two shockwave technologies | 19 treatment tips | Three dedicated modes | CE and ISO certificates | Three-year warranty
Two Professional Shockwave Technologies on One Platform
Electromagnetic Shockwave Technology
The electromagnetic handpiece uses a precision magnetic-coil mechanism to generate focused acoustic energy. Its concentrated delivery is designed for smaller treatment zones and applications that require precise energy placement.
Common applications include:
-
Focused musculoskeletal treatments
-
Tendon and soft-tissue programs
-
Localized pain-management support
-
Sports-injury rehabilitation
-
Erectile-function treatment protocols
-
Targeted physiotherapy applications
Pneumatic Ballistic Shockwave Technology
The pneumatic handpiece uses compressed air to accelerate an internal projectile. The resulting impact creates radial pressure waves that disperse through a broader tissue area.
Common applications include:
-
Large soft-tissue areas
-
Cellulite treatments
-
Body-contouring programs
-
Broad physiotherapy applications
-
Muscle and connective-tissue treatments
-
Sports-recovery programs
Integrated Dual-Technology Operation
The two handpieces allow practitioners to select focused electromagnetic energy or broader pneumatic pressure waves without purchasing separate systems.
This integrated configuration supports:
-
Precise and broad treatment options
-
Multiple professional applications
-
Customizable treatment protocols
-
Efficient switching between services
-
Reduced equipment requirements
-
Flexible clinical workflows
Select the Right Treatment Mode for Each Client
Erectile-Function Treatment Mode
The dedicated ED interface includes five mapped treatment zones, impact counting, round tracking, preload selection, and electromagnetic or pneumatic mode options.
Recommended applications:
-
Professional erectile-function protocols
-
Vascular-support treatment programs
-
Targeted acoustic-wave applications
-
Structured multi-session treatments
Recommended for:
-
Appropriately screened adult male clients
-
Specialist men’s wellness clinics
-
Qualified practitioners offering ED protocols
This application should only be provided within the practitioner’s permitted professional scope and according to applicable local requirements.
Anti-Cellulite Treatment Mode
The anti-cellulite interface provides body-area mapping and adjustable settings for different treatment zones.
Recommended applications:
-
Cellulite appearance treatments
-
Localized body-contouring programs
-
Skin-texture improvement
-
Soft-tissue stimulation
-
Body wellness treatments
Recommended for:
-
Clients concerned about visible cellulite
-
Clients seeking non-invasive body treatments
-
Clinics offering structured body-care programs
Physiotherapy Treatment Mode
The physiotherapy interface covers nine musculoskeletal regions and supports customizable frequency, energy, and impact settings.
Recommended applications:
-
Tendon and soft-tissue treatments
-
Sports-injury recovery programs
-
Chronic musculoskeletal conditions
-
Rehabilitation support
-
Localized pain-management programs
Recommended for:
-
Physiotherapy clients
-
Sports and recovery clients
-
Clients with professionally assessed musculoskeletal concerns
Sports-Recovery Program
Practitioners can select the appropriate electromagnetic or pneumatic handpiece according to the size, depth, and location of the target area.
Recommended applications:
-
Tendon overuse conditions
-
Muscle and soft-tissue recovery
-
Shoulder, elbow, knee, and ankle programs
-
Post-activity recovery support
Recommended for:
-
Athletes
-
Active adults
-
Fitness and rehabilitation clients
Electromagnetic Energy and Frequency Control
The electromagnetic handpiece offers adjustable focused-shockwave parameters for precise treatments.
| Setting | Available Range | Professional Purpose |
|---|---|---|
| Energy | 5–200mJ | Adjustable focused acoustic output |
| Frequency | 1–16Hz | Customizable pulse-delivery speed |
| Treatment Heads | Seven | Different focused applications |
| ED-Specific Heads | Two | Dedicated professional protocols |
| Preload Settings | Six | Customizable treatment response |
| Monitoring | Handpiece-mounted display | Real-time setting observation |
| Cooling | Built-in cooling fan | Supports continued operation |
Settings should be selected according to the treatment area, professional protocol, and client response.
Pneumatic Pressure and Frequency Control
The pneumatic handpiece provides adjustable radial pressure-wave settings for broader treatment areas.
| Setting | Available Range | Professional Purpose |
|---|---|---|
| Pressure | 1–6 Bar | Adjustable radial-wave intensity |
| Frequency | 1–21Hz | Customizable impact speed |
| Treatment Heads | Twelve | Broad treatment versatility |
| Head Types | Focus, radial, and flat | Different pressure-wave distributions |
| Head Diameters | 6–25mm | Small and large treatment zones |
| Tip Changing | Easy-change mechanism | Efficient treatment preparation |
| Mechanism | Compressed-air ballistic | Radial pressure-wave generation |
Nineteen Interchangeable Treatment Tips
The Dual Wave C includes seven electromagnetic heads and twelve pneumatic heads to support different treatment depths, areas, and professional applications.
| Tip Group | Quantity | Primary Applications |
|---|---|---|
| Electromagnetic Heads | Seven | Precise and focused treatment zones |
| ED-Specific Heads | Two of the seven electromagnetic heads | Professional erectile-function protocols |
| Pneumatic Focus Heads | Included within the twelve pneumatic heads | Concentrated radial treatment |
| Pneumatic Radial Heads | Included within the twelve pneumatic heads | General soft-tissue treatment |
| Pneumatic Flat Heads | Included within the twelve pneumatic heads | Broader surface coverage |
| Total Treatment Tips | Nineteen | Multi-application clinical coverage |
The exact tip should be selected according to its intended function, the treatment area, and the supplied professional protocol.
Adjustable Treatment Areas
Upper-Body Areas
The available heads and treatment settings support multiple upper-body physiotherapy and recovery applications.
Common treatment areas include:
-
Shoulder
-
Elbow
-
Hand and wrist
-
Upper back
-
Selected arm muscles and tendons
Lower-Body Areas
Focused or radial shockwave delivery can be selected according to the size and location of the lower-body treatment area.
Common treatment areas include:
-
Hip
-
Knee
-
Thigh
-
Achilles tendon
-
Foot and ankle
-
Plantar area
Body and Intimate Wellness Areas
Dedicated interfaces and specialized treatment heads support professionally assessed body and intimate wellness applications.
Common treatment areas include:
-
Abdomen
-
Waist
-
Buttocks
-
Inner and outer thighs
-
Legs
-
Suitable ED treatment zones
Professional Treatment Applications
| Treatment Category | Common Applications | Recommended Technology |
|---|---|---|
| Erectile-Function Programs | Professionally assessed vascular-support protocols | Electromagnetic or protocol-selected mode |
| Cellulite Treatments | Body texture and cellulite appearance | Pneumatic radial |
| Physiotherapy | Musculoskeletal and soft-tissue conditions | Electromagnetic or pneumatic |
| Sports Recovery | Muscle, tendon, and activity-related recovery | Protocol-dependent |
| Musculoskeletal Rehabilitation | Functional recovery and localized pain support | Focused or radial shockwave |
| Body Contouring | Abdomen, waist, thighs, buttocks, and legs | Pneumatic radial |
Common Musculoskeletal Applications
The Dual Wave C may be incorporated into professional protocols for suitable clients with:
-
Tennis elbow
-
Tendinitis and tendinopathy
-
Plantar fasciitis
-
Frozen shoulder
-
Achilles tendon concerns
-
Shoulder impingement
-
Rotator-cuff concerns
-
Suitable wrist and hand conditions
-
Knee and ankle concerns
-
Lumbar and hip discomfort
-
Chronic musculoskeletal concerns
-
Post-injury soft-tissue rehabilitation
Treatment suitability, diagnosis, parameters, and expected outcomes must be determined by an appropriately qualified professional.
How a Professional Session Works
Step 1: Client Consultation
Review the client’s medical history, current symptoms, diagnosis where applicable, medications, previous procedures, treatment goals, and possible contraindications.
Step 2: Treatment Mode Selection
Select the appropriate ED, anti-cellulite, or physiotherapy interface. Choose the electromagnetic or pneumatic handpiece according to the application.
Step 3: Tip and Parameter Selection
Install the appropriate treatment head and select the required energy or pressure, frequency, preload, and number of impacts.
Step 4: Shockwave Treatment
Apply suitable coupling medium when required and position the treatment head over the professionally identified area. Deliver the selected number of impacts while monitoring client response.
Step 5: Treatment Completion
Stop the program, remove the treatment medium, inspect the area, document the settings and impact count, and provide appropriate post-treatment recommendations.
Designed for Professional Treatment Environments
The Dual Wave C combines two shockwave technologies, specialized interfaces, and extensive treatment-head options in one clinical platform.
Key advantages include:
-
Electromagnetic and pneumatic technologies
-
Two independent professional handpieces
-
Seven electromagnetic treatment heads
-
Twelve pneumatic treatment heads
-
Nineteen treatment tips in total
-
Three dedicated treatment interfaces
-
Adjustable electromagnetic energy and frequency
-
Adjustable pneumatic pressure and frequency
-
Six preload settings
-
10.4-inch color touchscreen
-
Treatment-area mapping
-
Integrated impact counter
-
Built-in handpiece cooling
-
Rear-mounted storage tank
-
500W power consumption
-
110V and 220V compatibility
-
CE and ISO certificates
-
Three-year parts warranty
-
Professional training and lifetime support
Technical Specifications
| Specification | Details |
|---|---|
| Product Name | Wikbeauty Dual Wave C |
| Model | ESWT-DOUBLE-C |
| Technology | Electromagnetic and pneumatic ballistic shockwave |
| Input Voltage | AC 110V or 220V |
| Power Consumption | 500W |
| Display | 10.4-inch color touchscreen |
| Treatment Handpieces | Two: electromagnetic and pneumatic |
| Treatment Modes | ED, anti-cellulite, and physiotherapy |
| Electromagnetic Frequency | 1–16Hz |
| Electromagnetic Energy | 5–200mJ |
| Electromagnetic Heads | Seven, including two ED-specific heads |
| Pneumatic Frequency | 1–21Hz |
| Pneumatic Pressure | 1–6 Bar |
| Pneumatic Heads | Twelve |
| Pneumatic Head Types | Focus, radial, and flat |
| Pneumatic Head Diameters | 6–25mm |
| Total Treatment Tips | Nineteen |
| Preload Settings | Six |
| Special Features | Cooling system, storage tank, and impact counter |
| Certificates | CE and ISO certificates |
| Warranty | Three-year parts warranty |
| Support | Professional training and lifetime technical support |
What Is Included?
Standard Equipment
-
1 × Wikbeauty Dual Wave C main unit
-
1 × Electromagnetic shockwave handpiece
-
1 × Pneumatic ballistic shockwave handpiece
-
7 × Electromagnetic treatment heads
-
12 × Pneumatic treatment heads
-
19 × Total treatment tips
-
1 × Integrated 10.4-inch touchscreen
-
Built-in handpiece cooling system
-
Rear-mounted storage tank
-
Impact-counting system
-
Region-compatible power cable
-
Standard machine accessories
Documentation and Training
-
English user manual
-
Installation and operating guide
-
Safety and maintenance instructions
-
Dual-technology operation training
-
Electromagnetic parameter guidance
-
Pneumatic parameter guidance
-
Treatment-head selection guidance
-
ED protocol training
-
Anti-cellulite protocol training
-
Physiotherapy protocol training
-
Client-screening documentation
-
Professional training certificate
Professional Training and Ongoing Support
Every Dual Wave C system includes professional operating guidance to help practitioners use both technologies safely and consistently.
Training covers:
-
Machine installation and setup
-
Touchscreen and interface operation
-
Client consultation and screening
-
Electromagnetic handpiece operation
-
Pneumatic handpiece operation
-
Treatment-head selection
-
Energy, pressure, and frequency adjustment
-
Preload and impact-count settings
-
ED treatment interface
-
Anti-cellulite treatment interface
-
Physiotherapy treatment interface
-
Equipment cleaning and routine maintenance
-
Basic troubleshooting
Ongoing technical assistance is available by email, telephone, and WhatsApp.
Three-Year Warranty
The Wikbeauty Dual Wave C includes a three-year professional parts warranty, providing dependable after-sales protection for the equipment.
Warranty Coverage
The warranty covers eligible manufacturing defects and covered machine components under normal operating conditions. Technical guidance, troubleshooting assistance, and replacement-part coordination are available throughout the warranty period.
Treatment heads, projectiles, sealing components, and other parts subject to normal wear are not covered unless otherwise stated in the final order agreement.
Technical Support Process
-
Contact the Wikbeauty technical support team.
-
Provide the machine model and order information.
-
Describe the issue and provide photographs or video when requested.
-
A technician will assess the reported issue remotely.
-
Operating guidance or eligible replacement parts will be arranged.
-
Continued assistance will be provided until the reported issue is addressed.
Warranty Exclusions
The warranty does not cover normal wear, consumable components, damage caused by incorrect operation, unauthorized repair, accidental impact, unsuitable electrical supply, improper maintenance, liquid exposure, misuse, or failure to follow the operating manual.
Safety and Contraindications
A detailed medical consultation, professional assessment, and informed consent should be completed before treatment. The Dual Wave C should only be operated by appropriately qualified professionals within their permitted scope of practice.
Treatment may not be suitable for clients with:
-
Pregnancy or suspected pregnancy
-
Pacemakers or implanted electronic devices
-
Active thrombosis or blood clots
-
Anticoagulant therapy without appropriate medical clearance
-
Malignant tumors or known cancer in the treatment area
-
Active skin infection
-
Open wounds within the treatment area
-
Severely impaired sensation
-
Active growth plates in children
-
Recent surgery within the treatment area
-
Metal implants requiring medical clearance
-
Serious medical conditions requiring physician supervision
Additional considerations for ED treatments include:
-
Active infection or inflammation
-
Penile implants or prostheses
-
Unexplained pain, lesions, or bleeding
-
Conditions requiring specialist medical assessment
Client eligibility, treatment parameters, and medical clearance must be determined according to the application and applicable professional requirements.
Operating Precautions
-
Inspect the machine, handpieces, cables, and heads before treatment.
-
Select the correct handpiece and treatment head.
-
Begin with conservative settings.
-
Increase energy or pressure progressively according to response.
-
Use appropriate coupling medium where required.
-
Monitor client comfort throughout the session.
-
Do not treat prohibited anatomical areas.
-
Record treatment settings and impact counts.
-
Clean and disinfect reusable components after treatment.
-
Follow the supplied maintenance schedule.
-
Stop treatment if unexpected or severe discomfort occurs.
Intended Professional Users
The Wikbeauty Dual Wave C is intended for appropriately qualified and trained operators working in:
-
Physiotherapy clinics
-
Rehabilitation centers
-
Sports-medicine facilities
-
Musculoskeletal treatment practices
-
Men’s wellness clinics
-
Medical spas
-
Body-contouring clinics
-
Integrated wellness centers
-
Qualified medical and allied-health practices
Practitioners must review local licensing, insurance, medical-supervision, and scope-of-practice requirements before offering shockwave treatments.
Why Choose the Wikbeauty Dual Wave C?
Two Shockwave Technologies
The system combines focused electromagnetic energy and radial pneumatic pressure waves, supporting precise and broad-area applications on one platform.
Nineteen Treatment Tips
Seven electromagnetic heads and twelve pneumatic heads provide extensive treatment flexibility for different anatomical areas and professional protocols.
Three Dedicated Interfaces
Separate ED, anti-cellulite, and physiotherapy modes streamline parameter selection, body-area mapping, impact counting, and treatment documentation.
Customizable Professional Settings
Adjustable energy, pressure, frequency, preload, and impact settings allow professionals to personalize each session.
Complete Professional Support
The package includes dual-technology training, protocol guidance, technical assistance, CE and ISO certificates, and a three-year parts warranty.
Frequently Asked Questions
What is the Dual Wave C?
The Dual Wave C is a professional ESWT system that combines electromagnetic and pneumatic ballistic shockwave technologies on one platform.
What is the difference between the two handpieces?
The electromagnetic handpiece generates focused acoustic energy for precise treatment areas. The pneumatic handpiece creates radial pressure waves for broader soft-tissue areas.
How many treatment tips are included?
The system includes 19 tips: seven electromagnetic heads and twelve pneumatic heads.
Which treatment modes are available?
The touchscreen provides three dedicated interfaces for ED treatments, anti-cellulite programs, and physiotherapy applications.
What settings are available for the electromagnetic handpiece?
The electromagnetic handpiece provides an energy range of 5–200mJ and a frequency range of 1–16Hz.
What settings are available for the pneumatic handpiece?
The pneumatic handpiece provides a pressure range of 1–6 Bar and a frequency range of 1–21Hz.
Which areas can be treated?
Supported areas include the shoulder, elbow, wrist, lumbar area, hip, knee, foot, ankle, abdomen, waist, buttocks, thighs, legs, and suitable intimate wellness treatment zones.
Can the machine support ED treatment protocols?
Yes. It includes a dedicated ED interface and two specialized electromagnetic heads. This application should only be provided by appropriately qualified professionals following screening and applicable local requirements.
Can it be used for cellulite treatments?
Yes. The pneumatic handpiece and dedicated anti-cellulite interface support body-mapped cellulite and skin-texture programs.
Is treatment uncomfortable?
Client experience varies by treatment area, condition, energy level, and individual sensitivity. Intensity can be adjusted during treatment to maintain appropriate tolerance.
How many sessions are recommended?
The number and frequency of sessions depend on the application, client condition, professional assessment, and selected protocol. Treatment plans should be personalized rather than guaranteed.
Can both handpieces operate simultaneously?
The supplied configuration includes two independent handpieces and supports dual-handpiece operation. Actual use should follow the operating manual and selected professional protocol.
What certificates are included?
The system includes CE and ISO certificates.
What warranty is included?
The machine includes a three-year parts warranty with technical support and replacement-part coordination for eligible covered issues.
Is professional training included?
Yes. Training covers both shockwave technologies, the three treatment interfaces, treatment-head selection, parameter adjustment, client screening, safety, maintenance, and troubleshooting.
Add Dual-Technology Shockwave Therapy to Your Practice
The Wikbeauty Dual Wave C enables qualified clinics and wellness facilities to provide electromagnetic and pneumatic shockwave treatments using one professional platform.
Five key benefits:
-
Electromagnetic and pneumatic shockwave technologies
-
Nineteen treatment tips for precise and broad applications
-
Dedicated ED, anti-cellulite, and physiotherapy interfaces
-
Adjustable energy, pressure, frequency, and impact settings
-
CE and ISO certificates with a three-year warranty
Contact Wikbeauty for product pricing, package details, delivery information, professional training, and purchasing support.
ROI Calculator
See your investment recovery timeline
Estimated delivery: 5–10 business days after processing
$3,599.00
$3,599.00
Visible Results
See real toning and sculpting results in just a few sessions.
Comfortable Treatment
Designed for a smooth, pain-free experience from start to finish.
Discover Machines to Grow Your Practice
- Choosing a selection results in a full page refresh.
- Opens in a new window.