Smart Tecar Wave 3-in-1 Tecar RF EMS and Shockwave Therapy Machine for Pain Relief and Rehabilitation
This product will be available for sale in 2 weeks, but you can pre-order now to receive 10% discount!
Professional 3-in-1 TECAR, Acoustic-Wave and EMS System
Three Complementary Physiotherapy Modalities in One Platform
The Smart Tecar Wave integrates TECAR capacitive and resistive energy transfer, acoustic-wave therapy and electrical muscle stimulation within one professional system.
Dedicated handpieces and accessories allow qualified practitioners to use each modality independently according to the patient’s assessment and treatment plan.
The platform includes CET and RET TECAR handles, seven acoustic-wave applicators, EMS electrodes and vacuum-assisted EMS cups, providing flexible options for physiotherapy, sports rehabilitation and professionally supervised musculoskeletal applications.
Three modalities | CET and RET modes | Seven acoustic applicators | Three-year warranty
Three Professional Treatment Modalities
TECAR Therapy
TECAR uses radiofrequency energy between 300 and 450 kHz to produce controlled energy transfer within tissue.
The system includes two electrode formats:
-
CET — Capacitive Energy Transfer
-
RET — Resistive Energy Transfer
TECAR treatment may produce thermal or non-thermal effects depending on the selected settings, treatment technique and tissue characteristics.
Acoustic-Wave Therapy
The acoustic-wave module provides adjustable output from 5–200 mJ and a selectable frequency from 1–18 Hz.
Seven interchangeable applicators allow the practitioner to adapt surface contact to different professionally assessed treatment areas.
Electrical Muscle Stimulation
The EMS module delivers controlled electrical pulses at frequencies from 1–30 Hz.
It includes:
-
Reusable EMS electrode pads
-
Adjustable intensity from levels 1–20
-
Vacuum-assisted EMS cups
-
Multiple accessory sizes
-
Hands-free electrode placement
EMS can support selected professional programs involving muscle activation, neuromuscular re-education and rehabilitation.
CET and RET TECAR Modes
CET — Capacitive Energy Transfer
CET uses an insulated electrode to transfer energy through tissue.
It is generally associated with tissues containing relatively more water and electrolytes, such as:
-
Superficial muscle
-
Fascia
-
Selected soft-tissue areas
The system includes CET electrodes in:
-
20 mm
-
40 mm
-
60 mm
RET — Resistive Energy Transfer
RET uses an uninsulated electrode and is generally associated with tissues offering greater electrical resistance.
It may be incorporated into professional protocols concerning:
-
Tendon regions
-
Ligament areas
-
Joint-adjacent tissue
-
Denser connective tissue
-
Other professionally assessed structures
The system includes RET electrodes in:
-
20 mm
-
40 mm
-
60 mm
CET should not simply be described as “superficial,” nor RET as directly heating bones. Energy distribution depends on electrode placement, return-electrode positioning, tissue properties and device settings.
Additional TECAR Accessories
80 mm Fascia Applicator
The broad 80 mm applicator supports energy delivery over larger professionally selected treatment areas.
T-Shaped Handle
The T-shaped handle is designed for broad-area TECAR application and convenient manual movement.
Foot-Pad System
The foot-pad accessory provides an additional return-electrode or treatment configuration for appropriate lower-limb protocols.
Each accessory must be used according to the supplied operating instructions.
Seven Acoustic-Wave Applicators
The acoustic-wave module includes seven interchangeable heads.
Different applicator sizes may support:
-
Localized soft-tissue areas
-
Tendon-adjacent regions
-
Larger muscle groups
-
Broad surface treatment
-
More targeted contact
Applicator shape does not by itself determine treatment depth or establish that the wave is focused.
The practitioner must select the applicator according to the diagnosis, anatomy, device instructions and patient tolerance.
EMS and Vacuum-Assisted EMS
The EMS module delivers electrical stimulation through standard electrode pads or suction-assisted electrode cups.
Standard EMS Electrodes
Reusable pads provide controlled electrical stimulation to appropriately selected muscle groups.
Vacuum-Assisted EMS Cups
The vacuum cups help maintain electrode contact during hands-free operation.
The vacuum function does not provide proven fat reduction or automatically increase muscle growth. It primarily supports electrode positioning and contact.
Adjustable EMS Parameters
-
Intensity levels 1–20
-
Frequency range 1–30 Hz
-
Multiple electrode formats
-
Hands-free operation
Electrical stimulation must not be applied without proper knowledge of electrode placement, current pathways and contraindications.
Potential Professional Applications
Subject to the device’s authorized indications and professional assessment, the Smart Tecar Wave may be incorporated into programs concerning:
-
Selected musculoskeletal pain
-
Professionally assessed tendon concerns
-
Muscle tension
-
Neuromuscular re-education
-
Muscle activation
-
Sports rehabilitation
-
Post-injury rehabilitation
-
Range-of-motion programs
-
Selected joint-adjacent soft-tissue conditions
-
Other authorized physiotherapy applications
Clinical outcomes vary according to diagnosis, modality, settings and the broader rehabilitation program.
Claims That Should Not Be Made Without Specific Authorization
Smart Tecar Wave should not automatically be promoted for:
-
Erectile-dysfunction treatment
-
Pelvic-floor treatment without appropriate accessories and authorization
-
Permanent fat reduction
-
Cellulite elimination
-
Passive muscle building equivalent to exercise
-
Calcium-deposit elimination
-
Bone or cartilage regeneration
-
Guaranteed tissue healing
-
Treatment of every pain condition
-
Superior results from combining all three modalities
-
Unsupervised home use
Each medical or aesthetic indication must be supported by the device’s applicable certification, instructions and clinical evidence.
How the Three Modalities Work
TECAR Energy Transfer
Radiofrequency current passes between the active electrode and return electrode, producing controlled energy transfer through tissue.
The operator can adjust technique and parameters to create different treatment effects.
Acoustic-Wave Delivery
The acoustic module delivers mechanical pressure pulses through the selected applicator and coupling medium.
Its physical behavior depends on the generator design, energy output and applicator.
Electrical Muscle Stimulation
EMS applies electrical pulses through surface electrodes to stimulate peripheral nerves and muscle contractions.
Treatment effect depends on frequency, intensity, pulse characteristics, electrode placement and individual response.
Flexible Multimodality Workflows
Independent TECAR Treatment
Use CET or RET according to the tissue characteristics and professional treatment objective.
Independent Acoustic-Wave Treatment
Use the acoustic module with the selected applicator for an appropriately diagnosed condition.
Independent EMS Treatment
Use standard electrodes or vacuum-assisted cups for selected neuromuscular applications.
Sequential Treatment Planning
Qualified practitioners may include more than one modality in a rehabilitation plan when clinically justified.
The modalities should not automatically be used simultaneously or described as producing superior outcomes. Sequence, placement and compatibility must follow the user manual and professional training.
How a Professional Session Works
1. Clinical Assessment
The practitioner reviews the patient’s diagnosis, medical history, symptoms, implanted devices, treatment area and contraindications.
2. Modality Selection
TECAR, acoustic-wave therapy or EMS is selected according to the treatment goal.
3. Accessory Selection
The appropriate TECAR electrode, acoustic applicator or EMS electrode is installed.
4. Treatment Preparation
The patient is positioned correctly, and the required coupling medium, return electrode or EMS pads are applied.
5. Parameter Selection
Frequency, intensity, acoustic energy, treatment time and other settings are adjusted according to the professional protocol.
6. Controlled Treatment
The practitioner monitors patient comfort, skin response, muscle contractions and device performance.
7. Documentation and Follow-Up
Settings and patient response are documented, and further treatment is scheduled only when appropriate.
Possible temporary responses include warmth, redness, tenderness, muscle fatigue, soreness, bruising or skin irritation.
Technical Specifications
| Specification | Details |
|---|---|
| Product name | Smart Tecar Wave |
| Product type | Professional 3-in-1 physiotherapy system |
| Included modalities | TECAR, acoustic-wave therapy and EMS |
| TECAR modes | CET and RET |
| TECAR frequency | 300–450 kHz |
| CET electrode sizes | 20 mm, 40 mm and 60 mm |
| RET electrode sizes | 20 mm, 40 mm and 60 mm |
| Additional TECAR accessories | 80 mm fascia applicator, T-shaped handle and foot-pad system |
| Acoustic-wave output | 5–200 mJ |
| Acoustic-wave frequency | 1–18 Hz |
| Acoustic applicators | Seven |
| EMS intensity | Levels 1–20 |
| EMS frequency | 1–30 Hz |
| EMS accessories | Standard electrodes and vacuum-assisted cups |
| Input voltage | AC 110–240 V |
| Net weight | Approximately 33 kg |
| Package dimensions | 513 × 505 × 455 mm |
| Certifications | CE certified with applicable ISO documentation |
| Warranty | Three-year limited parts warranty |
| Support | Remote after-sales assistance |
Package dimensions should not be described as the machine’s installed dimensions unless confirmed separately.
What Is Included?
Main Equipment
-
One Smart Tecar Wave control system
-
Power cable suitable for the selected market
-
Required connection cables
-
Starter treatment consumables, where applicable
TECAR Accessories
-
One RET handle
-
20 mm RET electrode
-
40 mm RET electrode
-
60 mm RET electrode
-
One CET handle
-
20 mm CET electrode
-
40 mm CET electrode
-
60 mm CET electrode
-
80 mm fascia applicator
-
T-shaped treatment handle
-
Foot-pad system
-
Return electrode and connection components
Acoustic-Wave Accessories
-
One acoustic-wave handpiece
-
Seven interchangeable applicator heads
-
Applicator-removal components
-
Starter coupling gel
EMS Accessories
-
Standard EMS electrode pads
-
Vacuum-assisted EMS cups
-
EMS connection cables
-
Replacement electrode set, where included
Documentation and Certification
-
English user manual
-
CE certificate
-
Applicable ISO documentation
-
Installation guidance
-
Operating instructions for all three modalities
-
Cleaning and maintenance guidance
-
Basic troubleshooting assistance
-
Training certificate after completion
Final accessory quantities should be confirmed on the order quotation.
CE-Certified Professional System
The Smart Tecar Wave comes with:
-
CE Certificate
-
Applicable ISO Documentation
These documents are included with the machine and support its professional positioning and international distribution.
The system must only be marketed and used for the indications covered by its applicable certification and local regulatory status.
Professional Training and Support
Wikbeauty provides remote equipment training covering:
-
Machine installation
-
TECAR CET and RET operation
-
Electrode and return-plate placement
-
Acoustic-wave handpiece operation
-
Applicator selection
-
EMS electrode placement
-
Vacuum-cup operation
-
Basic parameter adjustment
-
Patient screening
-
Treatment monitoring
-
Cleaning and maintenance
-
Basic troubleshooting
A training certificate is provided after completion.
Equipment training does not replace professional physiotherapy education, medical diagnosis or any license required in the operator’s jurisdiction.
Three-Year Parts Warranty
The Smart Tecar Wave is supported by a three-year limited parts warranty and remote after-sales assistance.
Warranty Coverage
Subject to the official warranty terms, eligible manufacturing defects may be covered for:
-
Main control system
-
Internal electronic components
-
Display and control interface
-
Original TECAR handles
-
Original acoustic-wave handpiece
-
Original EMS and vacuum components
-
Original connectors
-
Other eligible machine parts
Electrodes, applicators, pads, seals and other wear components may have separate coverage terms.
Technical-Support Process
If a technical issue occurs, Wikbeauty will assist with:
-
Remote technical assessment
-
Guided diagnostic testing
-
Identification of the affected component
-
Confirmation of warranty eligibility
-
Replacement-part assistance where applicable
-
Remote installation guidance
Warranty Exclusions
The warranty does not normally cover:
-
Accidental or cosmetic damage
-
Incorrect operation or misuse
-
Unauthorized repairs or modifications
-
Incorrect voltage or electrical connection
-
Damage caused by dropping a handpiece
-
Improper cleaning or storage
-
Liquid entering electrical components
-
Normal electrode, pad or applicator wear
-
Unauthorized transportation damage
-
Failure to follow the operating manual
All coverage remains subject to Wikbeauty’s official warranty policy.
Contraindications and Safety Precautions
This system is professional therapeutic equipment and should only be operated by appropriately trained personnel.
Treatment may be contraindicated or require specialist assessment for patients with:
-
Pacemakers
-
Implantable cardioverter-defibrillators
-
Neurostimulators or medication pumps
-
Other active electronic implants
-
Pregnancy or suspected pregnancy
-
Active cancer in the treatment area
-
Open wounds or active infection
-
Significant bleeding disorders
-
Thrombosis
-
Severe cardiovascular conditions
-
Impaired sensation
-
Metal implants in or near the treatment area
-
Recent surgery
-
Other contraindications listed in the user manual
TECAR Precautions
The RF current pathway must be planned carefully. Avoid treatment over active implants, prohibited anatomical areas or compromised skin.
Acoustic-Wave Precautions
Do not apply acoustic energy over vulnerable organs, lung tissue, major blood vessels, the brain, spinal structures or other prohibited areas.
EMS Precautions
Electrode placement must not create a current pathway across the chest or near active implanted devices. Do not apply stimulation over the anterior neck, head or other prohibited areas.
This is not an exhaustive list. Medical clearance should be obtained whenever treatment suitability is uncertain.
Intended Professional Users
Smart Tecar Wave is suitable for:
-
Physiotherapy clinics
-
Rehabilitation centers
-
Sports-medicine practices
-
Orthopedic rehabilitation clinics
-
Licensed multidisciplinary centers
-
Qualified physical therapists
-
Appropriately trained healthcare professionals
The system is not intended for casual, consumer or unsupervised home use.
Why Choose Smart Tecar Wave?
Three Modalities in One Platform
Combine TECAR, acoustic-wave therapy and EMS without purchasing three separate control systems.
CET and RET Operation
Use capacitive and resistive electrode formats for different tissue characteristics and professional protocols.
Comprehensive Accessory Package
Multiple TECAR electrodes, seven acoustic applicators and standard or vacuum-assisted EMS options are included.
Adjustable Parameters
Select TECAR frequency, acoustic output and EMS intensity according to the treatment plan.
Hands-Free EMS Options
Vacuum-assisted cups support stable electrode placement during supervised treatment.
Professional Certifications
The machine comes with a CE certificate and applicable ISO documentation.
Long-Term Equipment Support
Professional training and a three-year limited parts warranty are included.
Frequently Asked Questions
What does “3-in-1” mean?
Smart Tecar Wave combines TECAR capacitive and resistive energy transfer, acoustic-wave therapy and electrical muscle stimulation.
What is the difference between CET and RET?
CET uses an insulated electrode and is generally associated with water-rich soft tissue. RET uses an uninsulated electrode and is generally associated with tissues offering greater electrical resistance.
Can all three modalities be used simultaneously?
They should only be combined or used sequentially when the device instructions and professional treatment plan permit it. Simultaneous use should not be assumed to be safe or superior.
Does it provide pelvic-floor therapy?
Surface EMS may support selected professional muscle-stimulation programs, but a specific pelvic-floor indication should not be claimed without appropriate accessories, protocols and authorization.
Does TECAR directly heat bones?
No. RET is associated with higher-resistance tissues, but it should not be described as selectively heating or regenerating bone.
Is treatment painless?
Patient experience varies. TECAR may create warmth, acoustic-wave treatment can be uncomfortable, and EMS causes muscle contractions or tingling.
Is training included?
Yes. Remote equipment training and a training certificate are included. This does not replace professional physiotherapy qualifications.
Is the machine CE certified?
Yes. Smart Tecar Wave comes with a CE certificate and applicable ISO documentation.
What does the warranty cover?
The three-year limited warranty covers eligible manufacturing defects affecting approved machine parts. Consumables, normal wear, accidental damage and misuse are excluded.
Expand Your Professional Physiotherapy Services
Smart Tecar Wave combines:
-
CET and RET TECAR therapy
-
Adjustable acoustic-wave technology
-
Standard and vacuum-assisted EMS
-
A complete professional accessory package
-
International voltage compatibility
Available for qualified professional use and subject to applicable local regulations.
Request Professional Pricing and Product Information
Product Comparison
Describe you product comparison grid
|
__ __ |
|
|---|---|
| Vendor |
Vendor - __ |
| SKU |
SKU - __ |
| Description |
Description - __ |
| Customizable title |
Customizable title - __ |
| Variant name |
Variant name - __ |
|
|
Compare products ( / )
Smart Tecar Wave 3-in-1 Tecar RF EMS and Shockwave Therapy Machine for Pain Relief and Rehabilitation
$2,539.00
Excluded Tax
This product will be available for sale in 2 weeks, but you can pre-order now to receive 10% discount!
Professional 3-in-1 TECAR, Acoustic-Wave and EMS System
Three Complementary Physiotherapy Modalities in One Platform
The Smart Tecar Wave integrates TECAR capacitive and resistive energy transfer, acoustic-wave therapy and electrical muscle stimulation within one professional system.
Dedicated handpieces and accessories allow qualified practitioners to use each modality independently according to the patient’s assessment and treatment plan.
The platform includes CET and RET TECAR handles, seven acoustic-wave applicators, EMS electrodes and vacuum-assisted EMS cups, providing flexible options for physiotherapy, sports rehabilitation and professionally supervised musculoskeletal applications.
Three modalities | CET and RET modes | Seven acoustic applicators | Three-year warranty
Three Professional Treatment Modalities
TECAR Therapy
TECAR uses radiofrequency energy between 300 and 450 kHz to produce controlled energy transfer within tissue.
The system includes two electrode formats:
-
CET — Capacitive Energy Transfer
-
RET — Resistive Energy Transfer
TECAR treatment may produce thermal or non-thermal effects depending on the selected settings, treatment technique and tissue characteristics.
Acoustic-Wave Therapy
The acoustic-wave module provides adjustable output from 5–200 mJ and a selectable frequency from 1–18 Hz.
Seven interchangeable applicators allow the practitioner to adapt surface contact to different professionally assessed treatment areas.
Electrical Muscle Stimulation
The EMS module delivers controlled electrical pulses at frequencies from 1–30 Hz.
It includes:
-
Reusable EMS electrode pads
-
Adjustable intensity from levels 1–20
-
Vacuum-assisted EMS cups
-
Multiple accessory sizes
-
Hands-free electrode placement
EMS can support selected professional programs involving muscle activation, neuromuscular re-education and rehabilitation.
CET and RET TECAR Modes
CET — Capacitive Energy Transfer
CET uses an insulated electrode to transfer energy through tissue.
It is generally associated with tissues containing relatively more water and electrolytes, such as:
-
Superficial muscle
-
Fascia
-
Selected soft-tissue areas
The system includes CET electrodes in:
-
20 mm
-
40 mm
-
60 mm
RET — Resistive Energy Transfer
RET uses an uninsulated electrode and is generally associated with tissues offering greater electrical resistance.
It may be incorporated into professional protocols concerning:
-
Tendon regions
-
Ligament areas
-
Joint-adjacent tissue
-
Denser connective tissue
-
Other professionally assessed structures
The system includes RET electrodes in:
-
20 mm
-
40 mm
-
60 mm
CET should not simply be described as “superficial,” nor RET as directly heating bones. Energy distribution depends on electrode placement, return-electrode positioning, tissue properties and device settings.
Additional TECAR Accessories
80 mm Fascia Applicator
The broad 80 mm applicator supports energy delivery over larger professionally selected treatment areas.
T-Shaped Handle
The T-shaped handle is designed for broad-area TECAR application and convenient manual movement.
Foot-Pad System
The foot-pad accessory provides an additional return-electrode or treatment configuration for appropriate lower-limb protocols.
Each accessory must be used according to the supplied operating instructions.
Seven Acoustic-Wave Applicators
The acoustic-wave module includes seven interchangeable heads.
Different applicator sizes may support:
-
Localized soft-tissue areas
-
Tendon-adjacent regions
-
Larger muscle groups
-
Broad surface treatment
-
More targeted contact
Applicator shape does not by itself determine treatment depth or establish that the wave is focused.
The practitioner must select the applicator according to the diagnosis, anatomy, device instructions and patient tolerance.
EMS and Vacuum-Assisted EMS
The EMS module delivers electrical stimulation through standard electrode pads or suction-assisted electrode cups.
Standard EMS Electrodes
Reusable pads provide controlled electrical stimulation to appropriately selected muscle groups.
Vacuum-Assisted EMS Cups
The vacuum cups help maintain electrode contact during hands-free operation.
The vacuum function does not provide proven fat reduction or automatically increase muscle growth. It primarily supports electrode positioning and contact.
Adjustable EMS Parameters
-
Intensity levels 1–20
-
Frequency range 1–30 Hz
-
Multiple electrode formats
-
Hands-free operation
Electrical stimulation must not be applied without proper knowledge of electrode placement, current pathways and contraindications.
Potential Professional Applications
Subject to the device’s authorized indications and professional assessment, the Smart Tecar Wave may be incorporated into programs concerning:
-
Selected musculoskeletal pain
-
Professionally assessed tendon concerns
-
Muscle tension
-
Neuromuscular re-education
-
Muscle activation
-
Sports rehabilitation
-
Post-injury rehabilitation
-
Range-of-motion programs
-
Selected joint-adjacent soft-tissue conditions
-
Other authorized physiotherapy applications
Clinical outcomes vary according to diagnosis, modality, settings and the broader rehabilitation program.
Claims That Should Not Be Made Without Specific Authorization
Smart Tecar Wave should not automatically be promoted for:
-
Erectile-dysfunction treatment
-
Pelvic-floor treatment without appropriate accessories and authorization
-
Permanent fat reduction
-
Cellulite elimination
-
Passive muscle building equivalent to exercise
-
Calcium-deposit elimination
-
Bone or cartilage regeneration
-
Guaranteed tissue healing
-
Treatment of every pain condition
-
Superior results from combining all three modalities
-
Unsupervised home use
Each medical or aesthetic indication must be supported by the device’s applicable certification, instructions and clinical evidence.
How the Three Modalities Work
TECAR Energy Transfer
Radiofrequency current passes between the active electrode and return electrode, producing controlled energy transfer through tissue.
The operator can adjust technique and parameters to create different treatment effects.
Acoustic-Wave Delivery
The acoustic module delivers mechanical pressure pulses through the selected applicator and coupling medium.
Its physical behavior depends on the generator design, energy output and applicator.
Electrical Muscle Stimulation
EMS applies electrical pulses through surface electrodes to stimulate peripheral nerves and muscle contractions.
Treatment effect depends on frequency, intensity, pulse characteristics, electrode placement and individual response.
Flexible Multimodality Workflows
Independent TECAR Treatment
Use CET or RET according to the tissue characteristics and professional treatment objective.
Independent Acoustic-Wave Treatment
Use the acoustic module with the selected applicator for an appropriately diagnosed condition.
Independent EMS Treatment
Use standard electrodes or vacuum-assisted cups for selected neuromuscular applications.
Sequential Treatment Planning
Qualified practitioners may include more than one modality in a rehabilitation plan when clinically justified.
The modalities should not automatically be used simultaneously or described as producing superior outcomes. Sequence, placement and compatibility must follow the user manual and professional training.
How a Professional Session Works
1. Clinical Assessment
The practitioner reviews the patient’s diagnosis, medical history, symptoms, implanted devices, treatment area and contraindications.
2. Modality Selection
TECAR, acoustic-wave therapy or EMS is selected according to the treatment goal.
3. Accessory Selection
The appropriate TECAR electrode, acoustic applicator or EMS electrode is installed.
4. Treatment Preparation
The patient is positioned correctly, and the required coupling medium, return electrode or EMS pads are applied.
5. Parameter Selection
Frequency, intensity, acoustic energy, treatment time and other settings are adjusted according to the professional protocol.
6. Controlled Treatment
The practitioner monitors patient comfort, skin response, muscle contractions and device performance.
7. Documentation and Follow-Up
Settings and patient response are documented, and further treatment is scheduled only when appropriate.
Possible temporary responses include warmth, redness, tenderness, muscle fatigue, soreness, bruising or skin irritation.
Technical Specifications
| Specification | Details |
|---|---|
| Product name | Smart Tecar Wave |
| Product type | Professional 3-in-1 physiotherapy system |
| Included modalities | TECAR, acoustic-wave therapy and EMS |
| TECAR modes | CET and RET |
| TECAR frequency | 300–450 kHz |
| CET electrode sizes | 20 mm, 40 mm and 60 mm |
| RET electrode sizes | 20 mm, 40 mm and 60 mm |
| Additional TECAR accessories | 80 mm fascia applicator, T-shaped handle and foot-pad system |
| Acoustic-wave output | 5–200 mJ |
| Acoustic-wave frequency | 1–18 Hz |
| Acoustic applicators | Seven |
| EMS intensity | Levels 1–20 |
| EMS frequency | 1–30 Hz |
| EMS accessories | Standard electrodes and vacuum-assisted cups |
| Input voltage | AC 110–240 V |
| Net weight | Approximately 33 kg |
| Package dimensions | 513 × 505 × 455 mm |
| Certifications | CE certified with applicable ISO documentation |
| Warranty | Three-year limited parts warranty |
| Support | Remote after-sales assistance |
Package dimensions should not be described as the machine’s installed dimensions unless confirmed separately.
What Is Included?
Main Equipment
-
One Smart Tecar Wave control system
-
Power cable suitable for the selected market
-
Required connection cables
-
Starter treatment consumables, where applicable
TECAR Accessories
-
One RET handle
-
20 mm RET electrode
-
40 mm RET electrode
-
60 mm RET electrode
-
One CET handle
-
20 mm CET electrode
-
40 mm CET electrode
-
60 mm CET electrode
-
80 mm fascia applicator
-
T-shaped treatment handle
-
Foot-pad system
-
Return electrode and connection components
Acoustic-Wave Accessories
-
One acoustic-wave handpiece
-
Seven interchangeable applicator heads
-
Applicator-removal components
-
Starter coupling gel
EMS Accessories
-
Standard EMS electrode pads
-
Vacuum-assisted EMS cups
-
EMS connection cables
-
Replacement electrode set, where included
Documentation and Certification
-
English user manual
-
CE certificate
-
Applicable ISO documentation
-
Installation guidance
-
Operating instructions for all three modalities
-
Cleaning and maintenance guidance
-
Basic troubleshooting assistance
-
Training certificate after completion
Final accessory quantities should be confirmed on the order quotation.
CE-Certified Professional System
The Smart Tecar Wave comes with:
-
CE Certificate
-
Applicable ISO Documentation
These documents are included with the machine and support its professional positioning and international distribution.
The system must only be marketed and used for the indications covered by its applicable certification and local regulatory status.
Professional Training and Support
Wikbeauty provides remote equipment training covering:
-
Machine installation
-
TECAR CET and RET operation
-
Electrode and return-plate placement
-
Acoustic-wave handpiece operation
-
Applicator selection
-
EMS electrode placement
-
Vacuum-cup operation
-
Basic parameter adjustment
-
Patient screening
-
Treatment monitoring
-
Cleaning and maintenance
-
Basic troubleshooting
A training certificate is provided after completion.
Equipment training does not replace professional physiotherapy education, medical diagnosis or any license required in the operator’s jurisdiction.
Three-Year Parts Warranty
The Smart Tecar Wave is supported by a three-year limited parts warranty and remote after-sales assistance.
Warranty Coverage
Subject to the official warranty terms, eligible manufacturing defects may be covered for:
-
Main control system
-
Internal electronic components
-
Display and control interface
-
Original TECAR handles
-
Original acoustic-wave handpiece
-
Original EMS and vacuum components
-
Original connectors
-
Other eligible machine parts
Electrodes, applicators, pads, seals and other wear components may have separate coverage terms.
Technical-Support Process
If a technical issue occurs, Wikbeauty will assist with:
-
Remote technical assessment
-
Guided diagnostic testing
-
Identification of the affected component
-
Confirmation of warranty eligibility
-
Replacement-part assistance where applicable
-
Remote installation guidance
Warranty Exclusions
The warranty does not normally cover:
-
Accidental or cosmetic damage
-
Incorrect operation or misuse
-
Unauthorized repairs or modifications
-
Incorrect voltage or electrical connection
-
Damage caused by dropping a handpiece
-
Improper cleaning or storage
-
Liquid entering electrical components
-
Normal electrode, pad or applicator wear
-
Unauthorized transportation damage
-
Failure to follow the operating manual
All coverage remains subject to Wikbeauty’s official warranty policy.
Contraindications and Safety Precautions
This system is professional therapeutic equipment and should only be operated by appropriately trained personnel.
Treatment may be contraindicated or require specialist assessment for patients with:
-
Pacemakers
-
Implantable cardioverter-defibrillators
-
Neurostimulators or medication pumps
-
Other active electronic implants
-
Pregnancy or suspected pregnancy
-
Active cancer in the treatment area
-
Open wounds or active infection
-
Significant bleeding disorders
-
Thrombosis
-
Severe cardiovascular conditions
-
Impaired sensation
-
Metal implants in or near the treatment area
-
Recent surgery
-
Other contraindications listed in the user manual
TECAR Precautions
The RF current pathway must be planned carefully. Avoid treatment over active implants, prohibited anatomical areas or compromised skin.
Acoustic-Wave Precautions
Do not apply acoustic energy over vulnerable organs, lung tissue, major blood vessels, the brain, spinal structures or other prohibited areas.
EMS Precautions
Electrode placement must not create a current pathway across the chest or near active implanted devices. Do not apply stimulation over the anterior neck, head or other prohibited areas.
This is not an exhaustive list. Medical clearance should be obtained whenever treatment suitability is uncertain.
Intended Professional Users
Smart Tecar Wave is suitable for:
-
Physiotherapy clinics
-
Rehabilitation centers
-
Sports-medicine practices
-
Orthopedic rehabilitation clinics
-
Licensed multidisciplinary centers
-
Qualified physical therapists
-
Appropriately trained healthcare professionals
The system is not intended for casual, consumer or unsupervised home use.
Why Choose Smart Tecar Wave?
Three Modalities in One Platform
Combine TECAR, acoustic-wave therapy and EMS without purchasing three separate control systems.
CET and RET Operation
Use capacitive and resistive electrode formats for different tissue characteristics and professional protocols.
Comprehensive Accessory Package
Multiple TECAR electrodes, seven acoustic applicators and standard or vacuum-assisted EMS options are included.
Adjustable Parameters
Select TECAR frequency, acoustic output and EMS intensity according to the treatment plan.
Hands-Free EMS Options
Vacuum-assisted cups support stable electrode placement during supervised treatment.
Professional Certifications
The machine comes with a CE certificate and applicable ISO documentation.
Long-Term Equipment Support
Professional training and a three-year limited parts warranty are included.
Frequently Asked Questions
What does “3-in-1” mean?
Smart Tecar Wave combines TECAR capacitive and resistive energy transfer, acoustic-wave therapy and electrical muscle stimulation.
What is the difference between CET and RET?
CET uses an insulated electrode and is generally associated with water-rich soft tissue. RET uses an uninsulated electrode and is generally associated with tissues offering greater electrical resistance.
Can all three modalities be used simultaneously?
They should only be combined or used sequentially when the device instructions and professional treatment plan permit it. Simultaneous use should not be assumed to be safe or superior.
Does it provide pelvic-floor therapy?
Surface EMS may support selected professional muscle-stimulation programs, but a specific pelvic-floor indication should not be claimed without appropriate accessories, protocols and authorization.
Does TECAR directly heat bones?
No. RET is associated with higher-resistance tissues, but it should not be described as selectively heating or regenerating bone.
Is treatment painless?
Patient experience varies. TECAR may create warmth, acoustic-wave treatment can be uncomfortable, and EMS causes muscle contractions or tingling.
Is training included?
Yes. Remote equipment training and a training certificate are included. This does not replace professional physiotherapy qualifications.
Is the machine CE certified?
Yes. Smart Tecar Wave comes with a CE certificate and applicable ISO documentation.
What does the warranty cover?
The three-year limited warranty covers eligible manufacturing defects affecting approved machine parts. Consumables, normal wear, accidental damage and misuse are excluded.
Expand Your Professional Physiotherapy Services
Smart Tecar Wave combines:
-
CET and RET TECAR therapy
-
Adjustable acoustic-wave technology
-
Standard and vacuum-assisted EMS
-
A complete professional accessory package
-
International voltage compatibility
Available for qualified professional use and subject to applicable local regulations.
Request Professional Pricing and Product Information
Take $50 OFF Any Order!
ROI Calculator
See your investment recovery timeline
In stock and ready to ship
5,000+ clinics trust Wikbeauty
Free worldwide delivery
Serving 150+ countries and counting
Estimated delivery: 5–10 business days after processing
Share:
$2,539.00
$2,539.00
$2,539.00
- 110V
- 220V
- US
- EU
- UK
- AU
Visible Results
See real toning and sculpting results in just a few sessions.
Comfortable Treatment
Designed for a smooth, pain-free experience from start to finish.
Discover Machines to Grow Your Practice
EMSLIM Pelvic Floor Chair - Restore Vaginal Muscle Tension and Improve Pelvic Health
$2,699.00
EMSLIM Pelvic Floor Chair - Restore Vaginal Muscle Tension and Improve Pelvic Health
$2,699.00
Emslim Machine – 4 Handles Professional Body Sculpting Device
$2,599.00
4 Handles Vertical Emslim Machine - Muscles Build
$3,799.00
4D Hifu Machine - Hifu Machine Price
$1,799.00
7D HIFU Machine - Hifu Device
$2,699.00
Vacuum butts and Breast Enlargement Device - BBL Machine
$499.00
Vacuum butts and Breast Enlargement Device - BBL Machine
$499.00
Shop this Collection
$1,199.00
Receives in 8 days.
From $2,599.00
Receives in 8 days.
$1,599.00
Receives in 8 days.
From $2,499.00
Receives in 8 days.
$1,129.00
Receives in 8 days.
$499.00
Receives in 8 days.
$2,599.00
Receives in 8 days.
$3,999.00
Receives in 8 days.
$999.00
Receives in 8 days.
$1,699.00
Receives in 8 days.
$3,999.00
Receives in 8 days.
From $2,399.00
Receives in 8 days.
$2,500.00
Receives in 8 days.
From $600.00
Receives in 8 days.
From $1,699.00
Receives in 8 days.
From $2,450.00
Receives in 8 days.
$2,169.00
Receives in 8 days.
$999.00
Receives in 8 days.
Wait — here's $50 off your order
Looks like you left something behind. Complete your order now and take $50 off with code COMEBACK50 — no minimum purchase required.
- Choosing a selection results in a full page refresh.
- Opens in a new window.