Smart Tecar Wave Máquina 3 en 1 Tecar RF EMS y Terapia de Ondas de Choque para Alivio del Dolor y Rehabilitación
$2,539.00
Excluded Tax
Estimated delivery: 5–10 business days after processing
$2,539.00
$2,539.00
DESCRIPTION
Professional 3-in-1 TECAR, Acoustic-Wave and EMS System
Three Complementary Physiotherapy Modalities in One Platform
The Smart Tecar Wave integrates TECAR capacitive and resistive energy transfer, acoustic-wave therapy and electrical muscle stimulation within one professional system.
Dedicated handpieces and accessories allow qualified practitioners to use each modality independently according to the patient’s assessment and treatment plan.
The platform includes CET and RET TECAR handles, seven acoustic-wave applicators, EMS electrodes and vacuum-assisted EMS cups, providing flexible options for physiotherapy, sports rehabilitation and professionally supervised musculoskeletal applications.
Three modalities | CET and RET modes | Seven acoustic applicators | Three-year warranty
Three Professional Treatment Modalities
TECAR Therapy
TECAR uses radiofrequency energy between 300 and 450 kHz to produce controlled energy transfer within tissue.
The system includes two electrode formats:
CET — Capacitive Energy Transfer
RET — Resistive Energy Transfer
TECAR treatment may produce thermal or non-thermal effects depending on the selected settings, treatment technique and tissue characteristics.
Acoustic-Wave Therapy
The acoustic-wave module provides adjustable output from 5–200 mJ and a selectable frequency from 1–18 Hz.
Seven interchangeable applicators allow the practitioner to adapt surface contact to different professionally assessed treatment areas.
Electrical Muscle Stimulation
The EMS module delivers controlled electrical pulses at frequencies from 1–30 Hz.
It includes:
Reusable EMS electrode pads
Adjustable intensity from levels 1–20
Vacuum-assisted EMS cups
Multiple accessory sizes
Hands-free electrode placement
EMS can support selected professional programs involving muscle activation, neuromuscular re-education and rehabilitation.
CET and RET TECAR Modes
CET — Capacitive Energy Transfer
CET uses an insulated electrode to transfer energy through tissue.
It is generally associated with tissues containing relatively more water and electrolytes, such as:
Superficial muscle
Fascia
Selected soft-tissue areas
The system includes CET electrodes in:
20 mm
40 mm
60 mm
RET — Resistive Energy Transfer
RET uses an uninsulated electrode and is generally associated with tissues offering greater electrical resistance.
It may be incorporated into professional protocols concerning:
Tendon regions
Ligament areas
Joint-adjacent tissue
Denser connective tissue
Other professionally assessed structures
The system includes RET electrodes in:
20 mm
40 mm
60 mm
CET should not simply be described as “superficial,” nor RET as directly heating bones. Energy distribution depends on electrode placement, return-electrode positioning, tissue properties and device settings.
Additional TECAR Accessories
80 mm Fascia Applicator
The broad 80 mm applicator supports energy delivery over larger professionally selected treatment areas.
T-Shaped Handle
The T-shaped handle is designed for broad-area TECAR application and convenient manual movement.
Foot-Pad System
The foot-pad accessory provides an additional return-electrode or treatment configuration for appropriate lower-limb protocols.
Each accessory must be used according to the supplied operating instructions.
Seven Acoustic-Wave Applicators
The acoustic-wave module includes seven interchangeable heads.
Different applicator sizes may support:
Localized soft-tissue areas
Tendon-adjacent regions
Larger muscle groups
Broad surface treatment
More targeted contact
Applicator shape does not by itself determine treatment depth or establish that the wave is focused.
The practitioner must select the applicator according to the diagnosis, anatomy, device instructions and patient tolerance.
EMS and Vacuum-Assisted EMS
The EMS module delivers electrical stimulation through standard electrode pads or suction-assisted electrode cups.
Standard EMS Electrodes
Reusable pads provide controlled electrical stimulation to appropriately selected muscle groups.
Vacuum-Assisted EMS Cups
The vacuum cups help maintain electrode contact during hands-free operation.
The vacuum function does not provide proven fat reduction or automatically increase muscle growth. It primarily supports electrode positioning and contact.
Adjustable EMS Parameters
Intensity levels 1–20
Frequency range 1–30 Hz
Multiple electrode formats
Hands-free operation
Electrical stimulation must not be applied without proper knowledge of electrode placement, current pathways and contraindications.
Potential Professional Applications
Subject to the device’s authorized indications and professional assessment, the Smart Tecar Wave may be incorporated into programs concerning:
Selected musculoskeletal pain
Professionally assessed tendon concerns
Muscle tension
Neuromuscular re-education
Muscle activation
Sports rehabilitation
Post-injury rehabilitation
Range-of-motion programs
Selected joint-adjacent soft-tissue conditions
Other authorized physiotherapy applications
Clinical outcomes vary according to diagnosis, modality, settings and the broader rehabilitation program.
Claims That Should Not Be Made Without Specific Authorization
Smart Tecar Wave should not automatically be promoted for:
Erectile-dysfunction treatment
Pelvic-floor treatment without appropriate accessories and authorization
Permanent fat reduction
Cellulite elimination
Passive muscle building equivalent to exercise
Calcium-deposit elimination
Bone or cartilage regeneration
Guaranteed tissue healing
Treatment of every pain condition
Superior results from combining all three modalities
Unsupervised home use
Each medical or aesthetic indication must be supported by the device’s applicable certification, instructions and clinical evidence.
How the Three Modalities Work
TECAR Energy Transfer
Radiofrequency current passes between the active electrode and return electrode, producing controlled energy transfer through tissue.
The operator can adjust technique and parameters to create different treatment effects.
Acoustic-Wave Delivery
The acoustic module delivers mechanical pressure pulses through the selected applicator and coupling medium.
Its physical behavior depends on the generator design, energy output and applicator.
Electrical Muscle Stimulation
EMS applies electrical pulses through surface electrodes to stimulate peripheral nerves and muscle contractions.
Treatment effect depends on frequency, intensity, pulse characteristics, electrode placement and individual response.
Flexible Multimodality Workflows
Independent TECAR Treatment
Use CET or RET according to the tissue characteristics and professional treatment objective.
Independent Acoustic-Wave Treatment
Use the acoustic module with the selected applicator for an appropriately diagnosed condition.
Independent EMS Treatment
Use standard electrodes or vacuum-assisted cups for selected neuromuscular applications.
Sequential Treatment Planning
Qualified practitioners may include more than one modality in a rehabilitation plan when clinically justified.
The modalities should not automatically be used simultaneously or described as producing superior outcomes. Sequence, placement and compatibility must follow the user manual and professional training.
How a Professional Session Works
1. Clinical Assessment
The practitioner reviews the patient’s diagnosis, medical history, symptoms, implanted devices, treatment area and contraindications.
2. Modality Selection
TECAR, acoustic-wave therapy or EMS is selected according to the treatment goal.
3. Accessory Selection
The appropriate TECAR electrode, acoustic applicator or EMS electrode is installed.
4. Treatment Preparation
The patient is positioned correctly, and the required coupling medium, return electrode or EMS pads are applied.
5. Parameter Selection
Frequency, intensity, acoustic energy, treatment time and other settings are adjusted according to the professional protocol.
6. Controlled Treatment
The practitioner monitors patient comfort, skin response, muscle contractions and device performance.
7. Documentation and Follow-Up
Settings and patient response are documented, and further treatment is scheduled only when appropriate.
Possible temporary responses include warmth, redness, tenderness, muscle fatigue, soreness, bruising or skin irritation.
Technical Specifications
SpecificationDetailsProduct nameSmart Tecar WaveProduct typeProfessional 3-in-1 physiotherapy systemIncluded modalitiesTECAR, acoustic-wave therapy and EMSTECAR modesCET and RETTECAR frequency300–450 kHzCET electrode sizes20 mm, 40 mm and 60 mmRET electrode sizes20 mm, 40 mm and 60 mmAdditional TECAR accessories80 mm fascia applicator, T-shaped handle and foot-pad systemAcoustic-wave output5–200 mJAcoustic-wave frequency1–18 HzAcoustic applicatorsSevenEMS intensityLevels 1–20EMS frequency1–30 HzEMS accessoriesStandard electrodes and vacuum-assisted cupsInput voltageAC 110–240 VNet weightApproximately 33 kgPackage dimensions513 × 505 × 455 mmCertificationsCE certified with applicable ISO documentationWarrantyThree-year limited parts warrantySupportRemote after-sales assistance
Package dimensions should not be described as the machine’s installed dimensions unless confirmed separately.
What Is Included?
Main Equipment
One Smart Tecar Wave control system
Power cable suitable for the selected market
Required connection cables
Starter treatment consumables, where applicable
TECAR Accessories
One RET handle
20 mm RET electrode
40 mm RET electrode
60 mm RET electrode
One CET handle
20 mm CET electrode
40 mm CET electrode
60 mm CET electrode
80 mm fascia applicator
T-shaped treatment handle
Foot-pad system
Return electrode and connection components
Acoustic-Wave Accessories
One acoustic-wave handpiece
Seven interchangeable applicator heads
Applicator-removal components
Starter coupling gel
EMS Accessories
Standard EMS electrode pads
Vacuum-assisted EMS cups
EMS connection cables
Replacement electrode set, where included
Documentation and Certification
English user manual
CE certificate
Applicable ISO documentation
Installation guidance
Operating instructions for all three modalities
Cleaning and maintenance guidance
Basic troubleshooting assistance
Training certificate after completion
Final accessory quantities should be confirmed on the order quotation.
CE-Certified Professional System
The Smart Tecar Wave comes with:
CE Certificate
Applicable ISO Documentation
These documents are included with the machine and support its professional positioning and international distribution.
The system must only be marketed and used for the indications covered by its applicable certification and local regulatory status.
Professional Training and Support
Wikbeauty provides remote equipment training covering:
Machine installation
TECAR CET and RET operation
Electrode and return-plate placement
Acoustic-wave handpiece operation
Applicator selection
EMS electrode placement
Vacuum-cup operation
Basic parameter adjustment
Patient screening
Treatment monitoring
Cleaning and maintenance
Basic troubleshooting
A training certificate is provided after completion.
Equipment training does not replace professional physiotherapy education, medical diagnosis or any license required in the operator’s jurisdiction.
Three-Year Parts Warranty
The Smart Tecar Wave is supported by a three-year limited parts warranty and remote after-sales assistance.
Warranty Coverage
Subject to the official warranty terms, eligible manufacturing defects may be covered for:
Main control system
Internal electronic components
Display and control interface
Original TECAR handles
Original acoustic-wave handpiece
Original EMS and vacuum components
Original connectors
Other eligible machine parts
Electrodes, applicators, pads, seals and other wear components may have separate coverage terms.
Technical-Support Process
If a technical issue occurs, Wikbeauty will assist with:
Remote technical assessment
Guided diagnostic testing
Identification of the affected component
Confirmation of warranty eligibility
Replacement-part assistance where applicable
Remote installation guidance
Warranty Exclusions
The warranty does not normally cover:
Accidental or cosmetic damage
Incorrect operation or misuse
Unauthorized repairs or modifications
Incorrect voltage or electrical connection
Damage caused by dropping a handpiece
Improper cleaning or storage
Liquid entering electrical components
Normal electrode, pad or applicator wear
Unauthorized transportation damage
Failure to follow the operating manual
All coverage remains subject to Wikbeauty’s official warranty policy.
Contraindications and Safety Precautions
This system is professional therapeutic equipment and should only be operated by appropriately trained personnel.
Treatment may be contraindicated or require specialist assessment for patients with:
Pacemakers
Implantable cardioverter-defibrillators
Neurostimulators or medication pumps
Other active electronic implants
Pregnancy or suspected pregnancy
Active cancer in the treatment area
Open wounds or active infection
Significant bleeding disorders
Thrombosis
Severe cardiovascular conditions
Impaired sensation
Metal implants in or near the treatment area
Recent surgery
Other contraindications listed in the user manual
TECAR Precautions
The RF current pathway must be planned carefully. Avoid treatment over active implants, prohibited anatomical areas or compromised skin.
Acoustic-Wave Precautions
Do not apply acoustic energy over vulnerable organs, lung tissue, major blood vessels, the brain, spinal structures or other prohibited areas.
EMS Precautions
Electrode placement must not create a current pathway across the chest or near active implanted devices. Do not apply stimulation over the anterior neck, head or other prohibited areas.
This is not an exhaustive list. Medical clearance should be obtained whenever treatment suitability is uncertain.
Intended Professional Users
Smart Tecar Wave is suitable for:
Physiotherapy clinics
Rehabilitation centers
Sports-medicine practices
Orthopedic rehabilitation clinics
Licensed multidisciplinary centers
Qualified physical therapists
Appropriately trained healthcare professionals
The system is not intended for casual, consumer or unsupervised home use.
Why Choose Smart Tecar Wave?
Three Modalities in One Platform
Combine TECAR, acoustic-wave therapy and EMS without purchasing three separate control systems.
CET and RET Operation
Use capacitive and resistive electrode formats for different tissue characteristics and professional protocols.
Comprehensive Accessory Package
Multiple TECAR electrodes, seven acoustic applicators and standard or vacuum-assisted EMS options are included.
Adjustable Parameters
Select TECAR frequency, acoustic output and EMS intensity according to the treatment plan.
Hands-Free EMS Options
Vacuum-assisted cups support stable electrode placement during supervised treatment.
Professional Certifications
The machine comes with a CE certificate and applicable ISO documentation.
Long-Term Equipment Support
Professional training and a three-year limited parts warranty are included.
Frequently Asked Questions
What does “3-in-1” mean?
Smart Tecar Wave combines TECAR capacitive and resistive energy transfer, acoustic-wave therapy and electrical muscle stimulation.
What is the difference between CET and RET?
CET uses an insulated electrode and is generally associated with water-rich soft tissue. RET uses an uninsulated electrode and is generally associated with tissues offering greater electrical resistance.
Can all three modalities be used simultaneously?
They should only be combined or used sequentially when the device instructions and professional treatment plan permit it. Simultaneous use should not be assumed to be safe or superior.
Does it provide pelvic-floor therapy?
Surface EMS may support selected professional muscle-stimulation programs, but a specific pelvic-floor indication should not be claimed without appropriate accessories, protocols and authorization.
Does TECAR directly heat bones?
No. RET is associated with higher-resistance tissues, but it should not be described as selectively heating or regenerating bone.
Is treatment painless?
Patient experience varies. TECAR may create warmth, acoustic-wave treatment can be uncomfortable, and EMS causes muscle contractions or tingling.
Is training included?
Yes. Remote equipment training and a training certificate are included. This does not replace professional physiotherapy qualifications.
Is the machine CE certified?
Yes. Smart Tecar Wave comes with a CE certificate and applicable ISO documentation.
What does the warranty cover?
The three-year limited warranty covers eligible manufacturing defects affecting approved machine parts. Consumables, normal wear, accidental damage and misuse are excluded.
Expand Your Professional Physiotherapy Services
Smart Tecar Wave combines:
CET and RET TECAR therapy
Adjustable acoustic-wave technology
Standard and vacuum-assisted EMS
A complete professional accessory package
International voltage compatibility
Available for qualified professional use and subject to applicable local regulations.
Request Professional Pricing and Product Information
WHY CHOOSE WIKBEAUTY®
Smart Tecar Wave combines three complementary modalities in one professional system, helping clinics offer a broader range of physiotherapy and rehabilitation services without purchasing separate platforms.
Key features include:
TECAR therapy with CET and RET modes
TECAR frequency: 300–450 kHz
CET electrodes: 20 mm, 40 mm, 60 mm
RET electrodes: 20 mm, 40 mm, 60 mm
80 mm fascia applicator
T-shaped TECAR handle
Foot-pad system
Acoustic-wave output: 5–200 mJ
Acoustic-wave frequency: 1–18 Hz
Seven acoustic-wave applicators
EMS intensity levels: 1–20
EMS frequency: 1–30 Hz
Standard EMS electrodes
Vacuum-assisted EMS cups
AC 110–240 V compatibility
CE certified with applicable ISO documentation
Three-year limited parts warranty
Remote after-sales assistance
TRAINING & CERTIFICATION
Wikbeauty provides remote equipment training covering:
Machine installation
TECAR CET and RET operation
Electrode and return-plate placement
Acoustic-wave handpiece operation
Applicator selection
EMS electrode placement
Vacuum-cup operation
Basic parameter adjustment
Patient screening
Treatment monitoring
Cleaning and maintenance
Basic troubleshooting
SPECIFICATIONS
Product Name: Smart Tecar Wave
Product Type: Professional 3-in-1 physiotherapy system
Included Modalities: TECAR, acoustic-wave therapy, EMS
TECAR Modes: CET and RET
TECAR Frequency: 300–450 kHz
CET Electrode Sizes: 20 mm, 40 mm, 60 mm
RET Electrode Sizes: 20 mm, 40 mm, 60 mm
Additional TECAR Accessories: 80 mm fascia applicator, T-shaped handle, foot-pad system
Acoustic-Wave Output: 5–200 mJ
Acoustic-Wave Frequency: 1–18 Hz
Acoustic Applicators: 7
EMS Intensity: Levels 1–20
EMS Frequency: 1–30 Hz
EMS Accessories: Standard electrodes and vacuum-assisted cups
Input Voltage: AC 110–240 V
Net Weight: Approximately 33 kg
Package Dimensions: 513 × 505 × 455 mm
Certifications: CE certified with applicable ISO documentation
Warranty: Three-year limited parts warranty
Support: Remote after-sales assistance
DELIVERY
The provided product information confirms:
Input Voltage: AC 110–240 V
Net Weight: Approximately 33 kg
Package Dimensions: 513 × 505 × 455 mm
Power Cable: Suitable for the selected market
Required connection cables: Included
Starter treatment consumables: Included where applicable
VOLUME DISCOUNT
Need multiple units for your physiotherapy clinic, rehabilitation center, sports-medicine practice, or distribution business?
Wikbeauty offers volume purchasing options for larger orders.
You can visit our dedicated Volume Discount page or contact us directly for current bulk-order pricing and purchasing support.
For larger orders, final accessory quantities should be confirmed on the order quotation before purchase.
ROI Calculator
See your investment recovery timeline

3-in-1 TECAR, Acoustic-Wave & EMS Physiotherapy System
The Smart Tecar Wave combines three professional physiotherapy modalities in one compact platform: TECAR therapy with CET and RET modes, acoustic-wave therapy, and electrical muscle stimulation. With multiple TECAR electrodes, seven acoustic-wave applicators, standard EMS electrodes, and vacuum-assisted EMS cups, the system gives qualified practitioners flexible treatment options for physiotherapy, sports rehabilitation, and professionally supervised musculoskeletal programs.
1. What is the Smart Tecar Wave?
The Smart Tecar Wave is a professional 3-in-1 physiotherapy system combining TECAR therapy, acoustic-wave therapy, and electrical muscle stimulation. It is designed for qualified practitioners working in physiotherapy, rehabilitation, sports medicine, and related professional settings.
2. What does “3-in-1” mean?
It means the system includes three treatment modalities in one platform: TECAR with CET and RET modes, acoustic-wave therapy, and EMS. Each modality can be selected according to the patient assessment and professional treatment plan.
3. What is the difference between CET and RET TECAR?
CET uses an insulated electrode and is generally associated with softer, water-rich tissues such as superficial muscle and fascia. RET uses an uninsulated electrode and is generally associated with tissues offering greater electrical resistance, such as tendon, ligament, and denser connective-tissue areas.
4. What frequency does the TECAR function use?
The TECAR module operates between 300 and 450 kHz. The system includes both CET and RET electrode formats for different professional treatment protocols.
5. What is acoustic-wave therapy used for?
The acoustic-wave module delivers mechanical pressure pulses through interchangeable applicators. It may be incorporated into professionally assessed programs for selected soft-tissue, tendon-adjacent, muscle, rehabilitation, and musculoskeletal applications.
6. What are the acoustic-wave settings?
The supplied specification lists an adjustable acoustic-wave output of 5–200 mJ and a frequency range of 1–18 Hz. The machine also includes seven interchangeable acoustic-wave applicators.
7. What does the EMS function do?
The EMS module delivers controlled electrical pulses through standard electrode pads or vacuum-assisted cups. It may support selected professional programs involving muscle activation, neuromuscular re-education, and rehabilitation.
8. What are the EMS settings?
The EMS module provides intensity levels from 1–20 and a frequency range of 1–30 Hz. It can be used with standard reusable electrodes or vacuum-assisted EMS cups.
9. Can all three technologies be used in one treatment plan?
Qualified practitioners may include more than one modality in a structured rehabilitation plan when clinically justified. However, the modalities should not automatically be used simultaneously, and treatment sequence and compatibility should follow professional training and the user manual.
10. What areas or conditions can the Smart Tecar Wave be used for?
According to the supplied information, potential professional applications include selected musculoskeletal pain, tendon concerns, muscle tension, muscle activation, neuromuscular re-education, sports rehabilitation, post-injury rehabilitation, range-of-motion programs, and selected joint-adjacent soft-tissue conditions.
11. Is the treatment painful?
Treatment experience varies by modality and individual response. TECAR may create warmth, acoustic-wave treatment can be uncomfortable, and EMS may cause tingling or muscle contractions. Settings should be adjusted according to patient tolerance and professional protocol.
Discover Machines to Grow Your Practice
- Seleccionar una opción actualiza la página completa.
- Se abre en una ventana nueva.